Use of acoustic methods and current flow measurement in battery research

Resource type: 
Supplier article
Author(s): 
3P Instruments
Format: 
pdf
Date of creation: 
22 July 2022
Library code: 
13502

In this article, the possible uses of the three methods “acoustic attenuation spectroscopy for particle size”, “electroacoustic for zeta potential” and “electric current measurement for electric conductivity in organic solvents” for NMR battery production process were investigated.

The acoustic methods are in particular ideal to characterize the suspensions used for electrode manufacturing and separator coating due to their possibility to measure in original concentrated systems.

The electric current measurement on the other hand is predestined to check the liquid electrolyte regarding water contamination. Thus, all systems can play an important role both in cell development and later in quality checks during battery production.